What’s New in SB

4.43

  • New Localise Lamps process to speed up simultaneous commissioning of multiple fixtures on floor plan. The previous single-lamp process can be reenabled in the Localise Lamps dialog.

  • New Connection Settings > DyNet Mute option to prevent accidental changes upon connecting.

  • New floor plan tools: Set Background Scale Factor > Measure Distance and Show/Hide Layers > Global Coordinates.

  • PDDEG-S/PDEG/PDEB: Ports > General > Route RS-485 bad packets to trunk option enables gateways to route bad packets received on the RS-485 spur to the trunk port inside a valid DyNet2 message for analysis.

  • Added support for LED strip fixture profiles.

4.42

  • Added gateway TCP port connection option

  • Improved device/logical preset synchronisation

4.41

  • Changed the Action Column description in DDNG485-DMX-Rx

  • Updated Bridge Configuration Wizard

4.40

  • Added DDC116 signal dimming controller

4.39

  • Add new area property to configure the BLA (Base Link Area) for all outputs in the area

  • Support DALI diagnostics tab for DDBC320-DALI that can be used to detect DALI network issues

  • Support sending message to trigger button presses from button editor. Supported on DACM firmware version 3.19

  • Quick Start Guide under Help menu now links to browser-based searchable documentation

  • Support editing Indoor Positioning System sites opened from retail cloud. Add, remove and modify lights, Bluetooth beacons and analytic zones

  • Improve configuration of Day Rhythm Feature using Synchronise button on gateway Rhythm Send tab

  • Add persistent memory tasking feature on DDBC120-DALI, DDRC420, DDRC1220

4.38

  • Renamed DALI ballasts to DALI drivers

  • Support Enable / Disable All check box for Ethernet Trunk connections

4.37

Minor bug fixes

4.36

BacNET on PDDEG-S

  • Supported on a PDDEG-S firmware version 1.24 onwards without constraining any of the current feature set of this gateway

  • Configured in System Builder with a very simple wizard

  • Trial licence allows you to set the device up and test it will the licence request is processed

  • Licences available for 100, 1000, 5000 and 10000 point setups

  • Offers the point types available today in the JACE plus 2 additional binary point types representing a high level overview of device offline and lamp/driver failure

New DDNG485, DDNG485-DMX-TX, DDNG485-DMX-RX

  • Support configuring the new DDNG485 gateway

  • New DDNG485-DMX-TX and DDNG485-DMX-RX support the full 512 DMX channels

  • Use 'Change Device Type' to upgrade existing DDNG485 to new device

Simplified Commissioning

  • Ethernet devices and their available open ports can now be discovered by mDNS using Insert Devices from Network - Discover Network button. Once these devices are added to the job SystemBuilder will be able to immediately connect directly to these devices over Ethernet

  • Improvements in shape recognition to better detect fixtures on floorplans

  • Update Commissioning Assistant make steps easier to follow

  • Allow Antumbra and Revolution LED Indicator Enable property to be set per button